CDX Range (Conventional)

CCP-E Conventional Call Point

The CCP-E is a conventional break-glass call point based upon the industry standard KAC world series housing.

CCP-E IS Intrinsically Safe Call Point

The CCP-E IS can be used in hazardous areas and is fully approved to BS5839 Part 2.

Hochiki's CDX (Conventional) Range of Detectors

From left: DCD-AE3 and DCD-CE3 Combined Heat Detectors, SLR-E3 Photoelectric Smoke Detector, DFJ-AE3 and DFJ-CE3 Fixed Temperature Heat Detector.

DCD-1E-IS Intrinsically Safe Conventional Rate of Rise Heat Detector

The DCD-1E-IS can be used in hazardous areas and incorporates at 60 degrees fixed temperature element, a thermistor and linearising circuit to provide an accurate linear response to heat.

DFG-60E Conventional Waterproof Heat Detector

The DFG-60E is a 60 degree fixed temperature heat detector which uses a bi-metallic strip to sense temperature change, therefore consuming no standby current and providing high reliability. It is particularly suited to environments which are exposed to high levels of condensation or are hosed down.

DFJ-CE3 Conventional Fixed Temperature Heat Detector (90oC, 60oC)

Model DFJ-CE3 is a 90 degree/60 degree Fixed Temperature Heat Detector using a thermistor and linearising circuit to provide an accurate linear response Heat Detector. A third terminal provides integral remote indicator output.

HF-24  Ultra-Violet Flame Detector

The HF-24 Flame Detector detects the presence of flame within its field of view by sensing the ultraviolet radiation emitted.

SL3-E3 Conventional Photoelectric Smoke Detector

The SL3-E3 is a photoelectric Smoke Detector, which is fully compatible with the majority of existing Conventional systems. An integral third terminal provides remote indicator output and the wide voltage range means the SLR-E3 can be installed within security systems.

Hochiki's Intrinsically Safe Detector (Left: SLR-E-IS, Right: DCD-1E-IS)

These conventional detectors are designed to be used in hazardous areas and are fully approved by BASEEFA.

Marine Approved Conventional Range

Hochiki's range of Marine-Approved devices includes a photoelectric Smoke Detector, Heat Detector, Bases and surface-mount back box. All are certificated by Lloyd's Register Det Norske Veritas and Germanischer Lloyd.

SLR-E-IS Intrinsically Safe Conventional Photoelectric Smoke Detector

The SLR-E-IS is designed to be used in hazardous areas and incorporates a remote indicator output and a removable chamber for easy maintenance.

SPB-ET Optical Beam Smoke Detector

The SPB-ET is a two wire beam detector consisting of an emitter and receiver that operates at distances of 5-100m providing a maximum of 1500 square metres coverage.

SPB-ET Optical Beam Smoke Detector

The SPB-ET is powered directly from the zone, so no auxiliary power supplies are required. When the zone is reset the detector is reset automatically and the unit can also be interfaced to Hochiki's ESP system by using a CHQ-MZ or CHQ-Z module.

SRA-ET Reflective Beam Smoke Detector

The SRA-ET comes complete over distance of 5-30m, thus giving a maximum coverage of 450 square metres.

SRA-ET Reflective Beam Smoke Detector

The SRA-ET comes complete with a Reflector and Termination Module which fits directly on to a standard U.K. dual back box, this allows the detector to be surface or flush mounted.

YBN-R/6 Conventional Electronics Free Base

The YBN-R/6 is fully compatible with the majority of existing conventional fire alarm control panels and is supplied with square cable clamps for secure and reliable cable termination.

YBO-R/6PA Conventional Detector Base for 2-Wire Systems

Model YBO-R/6PA is a Conventional Detector Mounting Base for 2-Wire systems where detectors and sounders are on the same zone cables.

YBO-R/6RS Conventional Latching Relay Base (with Schottky Diode line monitoring)

A Conventional Detector Mounting Base associated with the New CDX Range of Detectors and is fully compatible with the majority of existing conventional fire alarm control panels

YBN-R/4(IS) Conventionally Intrinsically Safe Base

The YBN-R/4(IS) is designed to be used in hazardous areas and is fully compatible with the majority of existing conventional fire alarm control panels.